Connect the power:
•
Position the power cable away from the door curtain and any moving
parts.
•
Plug the opener into a nearby power point and turn ON.
•
The opener courtesy LEDs should turn ON.
•
The opener must now be programmed for :
1. DOOR TRAVEL LIMITS (Section 14.2)
2. RIGHT OR LEFT HAND OPERATION (Section 14.6)
3. FORCE SETTING (Section 14.3)
14. Basic Function Setting and Applying
14.1 Learning the Receiver and Transmitter
Coding Transmitters:
Press and hold the "Code"button for 1 second until the led dot is on. Press
button on transmitter once, the dot will go off, press the same transmitter
button again and the dot will flash fast several times, and then return to
standby mode. The transmitter is now coded into the receiver.
Repeat the above steps to code more transmitters. The receiver has the
capacity to store 20 transmitters.
If the LED display flashes "F" and returns to standby mode (after you have
pressed the Code button), this indicates that the memory storage is full (20
transmitters). Follow the steps below to delete all transmitters that are stored in
the receiver memory: Press and hold on"CODE"button for more than 8
seconds until the LED flashes "C", all the stored codes are deleted. Only the
matched switch on the transmitter is available.
NOTE: If failed to match the transmitter within 20 seconds, then it will return to
standby mode automatically.
14.2 Travel Limit Setting Opening & Closing Force Self-learning
Press and hold the "SET" button for 3 seconds until the LED flashes "1". Press
"SET" button again for 1 second. "1" should now display as steady (not
flashing).
Then adjust the up limit by pressing "UP" button.
Fine-tune "UP" or "DOWN" button to determine the final up limit position (the
LED flashes "n" or "u" during opening or closing), then press "SET" button, the
display will show "2" automatically.
Adjust the down limit by pressing "DOWN" button.
Fine-tune "UP" or "DOWN" button to determine the final down limit position (the
LED flashes "n" or "u" during opening or closing), then press "SET" button.
When pressing the button to operate the opener, if the opener stops after
moving a little, and LED flashes "H" or "C", this indicates there is no hall signal
or the opener is overloaded.
11