GarageAce R5 설치 지침 매뉴얼 - 페이지 12
{카테고리_이름} GarageAce R5에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. GarageAce R5 20 페이지. Roller garage door opener
The opener will operate a cycle automatically to remember the limit positions
and the original o pening & closing force, then return to standby mode.
During learning, if the door stops unusually, and flashes "Ξ", "C", "O", "L" for
5 seconds, this indicates there's no hall signal, overload, overtime, or wrong
limit setting.
14.3 Safety Reverse Force Adjustment
Press and hold the "SET" button for 3 seconds until the LED flashes "1".
Press "UP" or "DOWN" button until LED flashes "2", then press "SET" button.
It's now in force adjustment mode. The LED displays the current set force.
Press "UP" button to increase the force or "DOWN" button to decrease the
force. The maximum force is 9 and the minimum is 1. Press "SET" button to
confirm, then the opener returns to standby mode.
The default setting of Safety Reverse Force is 3.
14.4 IR Beam Setting (for optional accessory)
Press and hold the "SET" button for 3 seconds until the LED flashes "1".
Press "UP" or "DOWN" button until the LED flashes "3", press "SET" button.
It's now under IR Beam setting mode. The LED displays the current setting.
Press "UP" button, the LED displays "1", the IR Beam Function is available.
Press "DOWN" button, the LED displays "0" to cancel this function. Press
"SET" button to confirm. The opener returns to standby mode.
The default setting of IR Beam is "0".
Notice:
•
Close the IR Beam function when you don't use IR Beam sensor.
•
We urge you to consider fitting IR Beams to your new garage door
opener. In many countries these devices are compulsory to assist in
preventing serious injury or property damage. For your own peace of
mind and the safety of others please install this inexpensive safety
device.
14.5 Auto-close Setting (optional)
Press and hold the "SET" button for 3 seconds until the LED flashes "1".
Press "UP" or "DOWN" to increase or decrease, adjust the LED to flash "4",
then press "SET" button to enter into auto-close setting, the LED displays the
current setting.
Press "UP" or "DOWN" button to adjust the auto-close time. Press "UP"
button once, the auto-close time will increase 1 minute, the maximum time is
9 minutes. Press "DOWN" button once, the auto-close time decrease 1
minute. The auto-close function will be turned off when the LED displays "0".
Press "SET" button to confirm, the opener returns to standby mode.
The auto-close function can only be available when the door is fully open
and the IR Beam function is on.
The default setting is "0".
12