CORNING EDGE8 LC-MTP 설치 및 테스트

{카테고리_이름} CORNING EDGE8 LC-MTP에 대한 설치 및 테스트을 온라인으로 검색하거나 PDF를 다운로드하세요. CORNING EDGE8 LC-MTP 8 페이지. Tap module

CORNING EDGE8 LC-MTP 설치 및 테스트
related literature | Search www.corning.com/opcomm. Click on "Resources."
003-1002

Table of Contents

General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.
2.
Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.1
Laser Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.2
Cable Handling Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.
Tools and Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
4.
Connector and Adapter Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
5.
Calculating System Loss Budgets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
6.
The Functionality of the Tap Module Splitters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
7.
Installing an EDGE8™ LC-MTP Tap Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
8.
Referencing the Test Equipment for an LC-MTP Tap Module . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
9.
Testing EDGE8 LC-MTP Tap Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.

General

1.1
This procedure describes EDGE8™ LC-MTP
Tap Modules, which are available for both
multimode and single mode applications.
Compatible with all EDGE8 rack-mountable
connector housings, LC-MTP Tap modules have
twelve front-mounted shuttered LC adapters
and two rear-mounted MTP connectors
(Figure 1).
1.2
The module contains 12 fiber optic splitters
which divide the incoming optical signals into
two outputs, one for live link traffic and eight
for monitoring. The monitor traffic is routed
via the "TAP"-labeled MTP connector to a
monitoring device which filters the data and sends it to various software tools for analysis, where
it is then viewed in application-layer software for security threats, performance issues, or system
optimization.
IMPORTANT: Please note that Tap module systems have two outputs for each input, which may require
two power meters, and depending on the system configuration, possibly require an additional craftsperson
in another location.
STANDARD RECOMMENDED PROCEDURE 003-137-AEN | ISSUE 1 | JANUARy 2017 | PAGE 1 OF 8
EDGE8
Solution
EDGE8
LC-MTP
Module Installation and
Testing
003-137-AEN, Issue 1
HPA-0753-EDGE8
Tap
®
Figure 1