Garaventa Lift EVACU-TRAC CD7 소유자 매뉴얼 - 페이지 15
{카테고리_이름} Garaventa Lift EVACU-TRAC CD7에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Garaventa Lift EVACU-TRAC CD7 20 페이지. Emergency evacuation chair
1. Loosen the Rear Brake Cable
Sleeve lock nuts and adjust
their location on the
Positioning Screw to provide
approximately 13 mm (1/2 in)
of free movement in the
Brake Release Bar. This is
the amount of motion that
should occur when squeezing
the Brake Release Bar before
any movement of the Brake
Cable occurs. If more
adjustment is required you
can also use the Cable
Sleeve Positioning Screw at
the other end of the Cable
Sleeve, near the Brake
Release Bar. Tighten the
lock nuts after adjustment.
2. When you squeeze the Brake
Release Bar it should travel
until it just makes contact with
the lime green Handle. This
will allow you to comfortably
hold Brake Release Bar in its
released position when
pushing Evacu-Trac on flat
surfaces or descending a
stairway.
The Brake Release Bar travel
range is adjusted using the
Adjusting Screws that control
the Front Auxiliary Wheel
Retracting Arm. Loosen the
lock nuts and adjust as
required. Test the action of
the Brake Release Bar and
then tighten the lock nuts.
14