Installing the Sensor

1.
Mount the slip sensor vertically in a static pipe.
See Figure 8.
NOTE Glue 1" fittings with 793 IPS brand ABS/PVC
glue. Do not glue 2" fittings.
NOTE Sensor wires must be continuous and not
spliced. Solder all low voltage wire connections
when possible and always use grease-filled
wire nuts on low voltage connections.
2.
Connect the sensor wires as follows. Refer to
Figure 7, Control Box Wiring, page 10
Table 1, Sensor Wire Connections, shown below.
a.
Connect the black wire from the Sensor
Common probe to the yellow wire in the
control box using a wire nut.
b.
Connect the red wire from the Fill Sensor
probe to the yellow wire with the blue stripe
in the control box using a wire nut.
c.
Connect the white wire from the High Water
Sensor probe to the yellow wire with the red
stripe in the control box using a wire nut.
Table 1. Sensor Wire Connections
Sensor Wires
Black (Sensor Common Probe)
Red (Fill Sensor Probe)
White (High Water Sensor Probe)
|
Installation and Operation Manual
and
Control Box Wires
Yellow
Yellow/Blue Stripe
Yellow/Red Stripe
ENGLISH
SIDE VIEW
Do Not Submerge
Sensor Under
Water
Sensor Tips
TOP VIEW
Sensor
Figure 8. Slip Sensor on Static Pipe
Page 11
Cable
Extension
Pipe
1" Coupling
Sensor
Water Level
Cable