INSTALLATION
Electrical Requirements
This equipment is designed specifically for domestic purposes and the Company cannot
accept responsibility if it is used in any other type of installation.
For your own safety, the Company recommends that the appliances are installed by a
competent person - such as one who is registered with NICEIC (National Inspection Council
for Electrical Installation Contracting). The cookers should be installed in accordance with
the Latest Edition of the IEE Regulations.
WARNING: - THESE APPLIANCES MUST BE EARTHED
Electrical Connections
The Installer must check that the voltage shown on the rating plate corresponds with the house
electricity supply. The oven must be supplied via a suitable double pole isolating switch, having a
contact separation of at least 3 mm in all poles placed in a readily accessible position to the unit.
The maximum loading for the oven is 4.9 kW.
If the oven is to be wired into a connector unit, this may be positioned behind the oven providing
that following requirements are met:-
i)
The connector unit must not project from the wall more than 25 mm,
ii)
The top of the connector must not be more than 130 mm above floor level.
Remove the terminal cover at the rear of the base of the oven. Pass the cable through the cable
clamp and connect to the appropriate terminals provided. Allow sufficient cable so that the oven can
be set down on the floor whilst still connected up. Tighten the screws on the cable clamp and
replace the terminal cover. Make the connections.
These appliances conform to BS. EN 55014 regarding suppression of Radio and Television
reception interference.
Where a double oven is used a 32 amp double pole control switch should be used to feed the unit
using a suitably rated cable. Where a hob is fitted adjacent to an oven then a 45 Amp Double Pole
control switch should be used to feed both units via separate suitably rated cable. We recommend
2
minimum of 4mm
PVC insulated twin and earth cable conforming to BS 6004 for connection of
each appliance.
These appliances must not be installed over any other appliance that generates heat.
OVEN UNIT HOUSING CABINET
IMPORTANT
It is essential that the lower cupboard is constructed in the manner illustrated, i.e. having side, back
and roof panels so joined as to provide no apertures which could prevent access to the oven unit
when installed. The appliance is designed for mounting at a safe level into an oven housing unit
which must be secured.
a. The oven housing unit cabinet dimensions must comply with Fig. 4.
b. An air gap of 50 mm minimum must be provided at the rear of any top or bottom cupboards or
shelves Fig. 1.
c.
It is necessary that the cabinets are provided with unobstructed ventilation i.e. from adjacent
cabinetry. This can be done by either raising the base of the cabinets using feet (or spacers) or
alternatively by providing a slot in the cabinet plinth to the dimensions shown in Fig. 1.
Service Manual UK
8 of 39
English