DGF Fabrications N2 설치 및 유지 관리 지침 매뉴얼 - 페이지 11

{카테고리_이름} DGF Fabrications N2에 대한 설치 및 유지 관리 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. DGF Fabrications N2 14 페이지. Gas effect fires (natural gas & lpg) for decorative purposes only

Switching the on/off or ignition button:
Depress the control knob & turn counter clockwise. Gas will flow to the pilot burner, the piezo igniter will give
off a high voltage spark and the pilot burner will light. (More than one attempt may have to be made on first
lighting the fire) Keep the control knob depressed for approximately10 seconds to allow the thermocouple to
heat up.
Turn the control knob fully counter clockwise to release gas to the main burner and let go of the knob.
Control of gas flow.
Turning the control knob clockwise reduces the gas rate from the pre-set maximum to the preset minimum
setting. Turning between maximum and minimum does not actuate the piezo igniter. The control valve can
only be set on pilot by depressing the control knob and turning it to the pre-selected pilot position.
Switching off
Press control knob in and turn clockwise to OFF.
1. Close all doors and windows and check operation of controls and burn for 5 minutes.
2. Test for spillage of the flue products using a smoke match
3. Pass the lighted match along the top front edge, just inside the fire opening
4. If there is a small amount of spillage, run the fire for a further 10 minutes and re-test spillage
5. If there is still a small amount of spillage after the second test, disconnect the fire and seek expert
advice.
6. A smell may be experienced when the appliance is first commissioned. This is due to the new
components of the fire these odours will cease after the first few hours of burning.
Polythene bags used in the packaging of this appliance are a potential hazard to babies and young children
and must be disposed of IMMEDIATELY.
This appliance is fitted with an oxygen depletion sensing system which automatically shuts off the gas supply to
the main burner if the oxygen level in the room is depleted, due to lack of air or an obstructed flue
If the fire shuts down for any reason, attempt to re-start it. If there is a continuing problem, call in a specialist
engineer.
There are no user replacement parts in this appliance.
Units 1-3 Vulcan St, Edward St Industrial Estate, Darlington. DL1 2UL – Tel: 01325 281304; Fax: 01325 481889
LIGHTING & CONTROLLING THE FIRE

COMMISSIONING THE FIRE

DISPOSAL OF PACKAGING

IMPORTANT NOTES
DGF Fabrications;
11