Dell Force10 S55 매뉴얼 - 페이지 22
{카테고리_이름} Dell Force10 S55에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell Force10 S55 50 페이지.
Dell Force10 S55에 대해서도 마찬가지입니다: 빠른 시작 매뉴얼 (29 페이지)
The S55 supports stacking in either a ring or cascade topology. Dell Force10 recommends the ring
topology when stacking S55 switches, to provide redundant connectivity.
Figure 4-1. S55 stacking topology with 2-port 12G stacking module
Switch 1
Switch 2
Switch 3
While the diagram shows A-to-B connections, the ports are bi-directional, so you can connect A-to-A or
B-to-B, as shown below in examples of two-switch
or insert them into a cabinet before you make your stacking port connections. Insert one end of the
stacking cable into a stacking port, and insert the other end into a stacking port of the adjacent switch.
Hand-tighten all captive screws to ensure that the cable is secure in the connector.
Connect two S55s
2-port 12G stacking modules
As an option, when using the 2-port 12G stacking modules, insert a second cable into the other open stack
ports, as shown in
transfer between the units.
Starting with the S55 at the bottom of the stack:
• Insert one end of the first cable into Stack Port 48 (or 49).
• Insert the other end of the cable into Stack Port 48 (or 49) of the top.
• Insert a second cable into Stack Port 49 (or 48) of the bottom and top S55s.
22
|
Install the S55
48
49
48
49
48
49
Figure
4-2. The second cable provides both backup connectivity and increased data
Switch 1
48
Switch 2
48
Switch 3
48
(Figure 4-2
or
Figure
49
49
49
4-3). Rack-mount the switches