Dell Z9100-ON 설치 매뉴얼 - 페이지 17

{카테고리_이름} Dell Z9100-ON에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell Z9100-ON 43 페이지. Open networking
Dell Z9100-ON에 대해서도 마찬가지입니다: 설치 매뉴얼 (45 페이지), 설치 매뉴얼 (45 페이지)

Dell Z9100-ON 설치 매뉴얼
Figure 5. 1U Tool-less Configuration
2.
Align and seat the front flange pegs in the holes on the front side of the vertical post. See item 2.
3.
Repeat this procedure for the second rail.
4.
To remove each rail, pull on the latch release button on each flange ear and unseat each rail. See
item 3.

Configuring a Two-Post Flush-Mount

To configure a two-post flush-mount installation, follow these steps.
1.
For this configuration, remove the castings from the front side of each ReadyRails assembly. See the
following illustration, item 1. To remove the two screws from each front flange ear (on the switch
side of the rail) and remove each casting, use a Torx screwdriver. Retain the castings for future rack
requirements. It is not necessary to remove the back flange castings.
Install the Z9100–ON
17