Residential Steambath Generator Systems
5. R oute the end of the temperature probe cable with the
temperature probe through the wall into the steam room
as shown in Diagram 3.
Do not strain, staple, pinch or
IMPORTANT NOTE:
otherwise damage the probe cable.
6. With a minimal length of the cable exposed apply sili-
cone (provided) to the hole in the wall as required to
create a moisture seal as shown in Diagram 3.
7. Push the temperature cable and bulb into hole as
required to leave minimum 1/4 in. (6mm), maximum
1/2 in. (13mm) of the bulb exposed as shown below.
!
warning
Insure a minimum of 1/4 in. (6mm) of
the temperature bulb is exposed to the air. Failure to do so
may result in an inoperative control and a hazardous condi-
tion.
!
warning
The exposed area of the temperature
bulb must be free of silicone or any materials that prevent
direct exposure to the steam room air. Failure to do so may
interfere with the ability to sense temperature and may
result in excessive steam room temperatures.
1 ⁄2" (13 mm)
minimum
3 ⁄4" (90 mm)
maximum
Wall
SECTIONAL VIEW
S team R oom Interior
Diagram 3
Diagram 4
Silicone Sealant
Cable
INSTALLED REMOTE
TEMPERATURE PROBE
aquabrass.com