Note:
InfiniBand cables with QSFP to CX4 connectors are required when the HP BLc 4X DDR InfiniBand
Gen 2 Switch uplinks to an InfiniBand spine interconnect with CX4 connectors.
Figure 2-3 QSFP InfiniBand DDR/QDR Cable
2
1
The following list describes the callouts shown in
1.
InfiniBand cable
2.
QSFP connector release pull tab
3.
QSFP connector
Note:
The InfiniBand cables are not included in this kit and must be purchased separately.
Installing an InfiniBand Cable in the HP BLc 4X DDR InfiniBand Gen 2 Switch
To install an InfiniBand cable in the HP BLc 4X DDR InfiniBand Gen 2 Switch, follow these steps:
1.
Align the InfiniBand cable QSFP connector (see callout 1 in
DDR InfiniBand Gen 2 Switch port (see callout 2 in
2.
Insert the QSFP connector into the HP BLc 4X DDR InfiniBand Gen 2 Switch port (see callout
1 in
Figure
2-5) until it is fully engaged and locked.
Figure 2-4 Align the InfiniBand Cable with the HP BLc 4X DDR InfiniBand Gen 2 Switch Port
2
1
3
The following list describes the callouts shown in
3
2.2 Installing InfiniBand Cables in the HP BLc 4X DDR InfiniBand Gen 2 Switch
Figure
2-3:
Figure
2-4) with the HP BLc 4X
Figure
2-4).
Figure
2-4:
13