HP Xw460c - ProLiant - Blade Workstation 설치 지침 매뉴얼

{카테고리_이름} HP Xw460c - ProLiant - Blade Workstation에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. HP Xw460c - ProLiant - Blade Workstation 10 페이지. Mezzanine card installation instructions for supported hp proliant c-class bladesystem servers
HP Xw460c - ProLiant - Blade Workstation에 대해서도 마찬가지입니다: 구현 매뉴얼 (35 페이지), 오류 방지 매뉴얼 (12 페이지), 기술 백서 (12 페이지), 펌웨어 업데이트 (9 페이지), 설치 매뉴얼 (2 페이지), 자주 묻는 질문 매뉴얼 (14 페이지), 설정 포스터 (9 페이지), 설치 매뉴얼 (33 페이지), 관리 매뉴얼 (28 페이지), 하드웨어 매뉴얼 (23 페이지), 개요 (35 페이지), 사용자 설명서 (33 페이지), 최적화 매뉴얼 (13 페이지), 제한 보증 (10 페이지), 설치 지침 매뉴얼 (8 페이지), 설치 지침 (4 페이지), 설치 지침 (2 페이지)

HP Xw460c - ProLiant - Blade Workstation 설치 지침 매뉴얼
NVIDIA Quadro FX 560M installation instructions
HP ProLiant xw460c Blade Workstation
This kit contains a low-profile NVIDIA Quadro FX 560M graphics board. On an HP ProLiant xw460c Blade
Workstation that already contains a low-profile Quadro FX 560M board, a dual-graphics configuration can be
created by installing a second low-profile Quadro FX 560M board. Each Quadro FX 560M board supports two
monitors. For a four-monitor configuration, install two low-profile Quadro FX 560M boards.
Support for dual-graphics is provided on Microsoft® Windows® XP Professional only—dual-graphics is not
currently supported on Linux. The flowchart below shows the installation process to create a dual-graphics
Quadro FX 560M configuration—please review this flowchart carefully before proceeding. Steps 1-6 are
described subsequently.
Ensure that the correct BIOS and NVIDIA graphics driver are
STEP 1:
installed on the blade workstation. This is required to support dual-graphics.
STEP 2:
board is currently installed in the blade workstation.
This path will require
that you have two
low-profile Quadro
FX 560M boards
available.
Ensure that the RGS 5.1.1 (or later) is installed, and verify RGS operation.
STEP 6:
WARNING!
The NVIDIA Quadro FX 560M graphics board can only be installed in the HP ProLiant xw460c
Blade Workstation. The board is not compatible with the HP ProLiant BL460c Server Blade or any other
server blade—installing this card in a server blade will cause the server blade to malfunction.
*463919-002*
- 1 -
Use the Control Panel to determine what graphics
Quadro FX 560M
currently installed
Another type of
graphics board is installed
Open the blade workstation (if it
STEP 4B:
STEP 4B
isn't already open) and remove the current
graphics board. It will not be used further.
Insert the first low-profile Quadro FX 560M
STEP 5:
in the lower connector. Insert the second low-
profile Quadro FX 560M in the upper connector.
STEP 3:
Y
determine if a low-profile or high-profile
Quadro
Quadro FX 560M is installed.
?
FX 560M
N
© 2008 Hewlett-Packard Development Company, LP. The HP
Invent logo is a registered trademark of Hewlett-Packard
Development Company, L.P. Printed in the U.S.
Open the blade workstation to
N
low-profile
FX 560M installed
high
?
profile
low profile
Y
Remove the low-profile
STEP 4A:
Quadro FX 560M board. This is to
provide access to the connector
beneath the board.