1. Overview
The LS LPLI series controller combines the solar charge controller and LED constant
current driver in one unit. It is ideal for solar LED lighting, especially for the LED lamp
application, which requires dimmer function. The advanced pulse width modulation
charging methods enables system charging and discharging management to obtain the
most radical optimization. Make the system cost reduce and increase system flexibility.
Features:
Apply to lead-acid battery and lithium battery
Lithium battery self-activating function
Lithium battery low-temperature protection function
Intelligent power mode with 365-day lighting control technology
Load power reduction automatically
Load power limitation function
Maximum output efficiency of 96%
Digital precision constant current control and the control accuracy are less than±2%
Discharging power calculation and real-time energy statistics recording function
Configurable multiple load control modes, LED rated current, and the current
percentage
Load test function for detecting the system
Extensive electronic protections
Without any button, parameter setting via RC-10 and FC-01 with IR function.
Fully encapsulated PCB, IP68 protection
Aluminum housing for better cooling
2. Product Features
❶
Charging Status LED indicator
❷
Battery Status LED indicator
Temperature Sensor ※
❸
❹
PV Positive and Negative Wires
※ If the temperature sensor connection is short-circuited or open-circuit, the
controller charges or discharges the battery at 25℃ and no temperature
compensation.
3. Wiring
Reference for Serial connection of LED
System
Serial
Voltage
connection
5~18 LED
12V
24V
10~18 LED
DO NOT electric shock! With the built-in boost LED driver, the output
voltage is higher than the human safety voltage.
If the LED connection number is wrong, the load or controller is
WARNING
damaged.
The above LED (1W, 3.3V) is calculated. If the user uses the
unconventional LED, The actual LED voltage must less than the Max. Load
CAUTION
Output Voltage.
Connection Order
1) Connect components to the charge controller in the sequence, as shown in Figure 2
Wiring, and pay much attention to the "+" and "-." Please don't insert the fuse or turn on
the breaker during the installation. When disconnecting the system, reverse the order.
2) After powering on the controller, check the controller's battery LED indicator; it usually is
green. Otherwise, please refer to chapter 8.
3) Connect a fuse in series through battery positive (+) in the circuit. The battery circuit
fuse must be 1.25 to 2 times the rated current. The installed distance is within 150mm.
Load self-test function
The load is ON when the controller power on for 10 seconds. After 10 seconds, it restores
the working mode setting.
---with built-in LED Driver
Figure 1 Product Feature
❺
Battery Positive and Negative Wires
❻
Load Positive and Negative Wires
❼
Infrared Receiver Module
❽
Infrared LED
Min. Output
Max. Output
Voltage
Voltage
15V
30V
1
Tel:+86-10-82894896/82894112/+86-752-3889706
4. LED Indicators
Indicator
All
indicators
5. Load Working Mode
1) Manual Mode
2) Light ON/OFF(default)
3) Light ON + Timer
Light ON + Timer1
Light ON + Timer2
60V
60V
Light ON + Timer3
Item
LED Rated Current
Timer1
LED Rated Current Percentage
Timer2
LED Rated Current Percentage
F
Figure 2 Wiring
Color
Status
Green
On Solid
Green
Slowly Flashing(1Hz)
Green
Fast Flashing(4Hz)
Green
OFF
Green
On Solid
Green
Slowly Flashing(1Hz)
Green
Fast Flashing(4Hz)
Orange
On Solid
Red
On Solid
Red
Slowly Flashing(1Hz)
Green and
Flashing two times
orange
Turn-On voltage (Adjustable):
5V(12Vsystem), delay10min.
Turn-Off voltage (Adjustable):
6V(12Vsystem), delay10min.
Note: 24V system voltage×2
Default※
Mode1
Mode2/3
0.35A
2H
1H
100%
100%
2H
1H
80%
50%
2
Website:www.epever.com
Instruction
PV connection normal but low
voltage(irradiance) from PV, no
charging
In charging
PV reverse polarity
No PV voltage(night time) or PV
connection problem
Normal
Full
Over voltage
Under voltage
Over discharged
Battery Overheating
Set parameters successfully
Range
0-2.6A(LS101240LPLI)
0-2.0A(LS102460LPLI)
0-4.0A(LS101260/2024120LPLI)
00:00—23:59H
0—100%
00:00—23:59H