{카테고리_이름} DieHard 200.71225에 대한 운영자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. DieHard 200.71225 20 페이지. Microprocessor controlled, fully automatic operation battery charger with engine starter plus battery and alternator tester for 6 and 12-volt batteries
DieHard 200.71225에 대해서도 마찬가지입니다: 소유자 매뉴얼 (17 페이지)
may or may not have vent caps. Vent caps are located on top of the bat-
tery and provide a means to add distilled water when needed. Batteries
should be marked with their type. If charging a battery that is not marked,
check the manual of the item that uses the battery.
13.3
CHARgE RATE BUTTON
Use this button to set the maximum charge rate to one of the following:
•
2A SLOw CHARgE RATE:
those commonly used in garden tractors, snow mobiles and motorcycles.
The 2A rate is not intended to be used as a trickle charger for larger bat-
teries.
•
12A
FAST and 30A RAPId CHARgE RATE: Use for charging automo-
tive, marine, and deep cycle batteries. Not intended for industrial applica-
tions.
•
80A START:
down battery. Always use in combination with a battery.
NOTE: To turn OFF the charger, unplug the power cord from the wall
outlet.
14.
USINg THE BUILT-IN VOLT METER TO TEST BATTERY STATE OF
CHARgE
OVERVIEw
This battery charger has a built-in volt meter to test your battery's state
of charge. The charger does not have a built in load tester. As such, a
recently charged battery could have a temporarily high voltage due to
what is known as "surface charge." The voltage of such a battery will
gradually drop during the period immediately after the charging system is
disengaged. Consequently, the tester could display inconsistent values for
such a battery. For a more accurate reading, the surface charge should be
removed by temporarily creating a load on the battery, such as by turning
on lights or other accessories.
14.1
TESTINg SEqUENCE
battery state of charge:
1.
Connect the charger battery clamps to the battery.
2.
Connect the charger power cord to a 120V AC 2-prong wall outlet.
3.
If necessary, press the
indicated.
4.
Read the voltage on the digital display or press the display mode but-
ton to set the tester to BATTERY % to read the voltage as a percent of
charge.
Intended for charging small batteries such as
Provides 80 amps for cranking an engine with a weak or run
: There are four basic steps required to test the
BATTERY TYPE button until the correct type is