14.2
TESTER ANd CHARgER:
as a tester, not as a charger. To continue to use it as only a tester, avoid
pressing the CHARGE RATE button. Selecting a charge rate activates the
battery charger and deactivates the tester. Pressing the CHARGE RATE but-
ton when the 80A Start LED is lit (except during the 180 second cool down)
will shut off the charger and activate the tester.
14.3
POwER-UP IdLE TIME LIMIT:
after the battery is first powered up, the charger will automatically switch
from tester to charger, if a battery is connected. In that case, the battery
will be set for the 2A charge rate and 12V REGULAR battery type.
14.4
TESTER wITHOUT TIME LIMIT:
TERY TYPE button is pressed within the first ten minutes after the battery
is powered up, the unit will remain a tester (not a charger) indefinitely,
unless a charge rate is selected.
14.5
TESTINg AFTER CHARgINg:
tester to charger (by selecting a charge rate), it remains a charger. To
change the battery back to a tester, press the CHARGE RATE switch until
all charge rate LEDs are off.
14.6
TESTER STATUS LEds:
the status LEDs light under the following conditions:
•
The CHARGED (green) LED will light if a charged battery is tested.
•
The CHARGING (yellow) LED does not light in the battery test mode.
•
The CHECK (red) LED lights unless a properly connected battery is de-
tected.
•
When the tester display mode is set to
CHARGING LEDs won't light.
14.7
INITIAL PERCENT CALCULATION:
the first time after connecting a battery, the digital display will show three
dashes ("---") for a period as long as several seconds while the tester
analyzes the battery.
15.
USINg THE BUILT-IN ALTERNATOR TO TEST ALTERNATOR
OUTPUT
This battery charger has a built-in alternator tester that displays an esti-
mate of the alternator's relative output compared to normal alternators.
The Alternator % values displayed should be taken as general reference,
not precise diagnosis. The alternator tester functions the same as the
built-in volt meter (see previous section of this manual for details) with a
few differences.
When first turned on, the 71225 operates only
If no button is pressed within 15 minutes
If either the DISPLAY MODE or BAT-
After the unit has been changed from
When the 71225 is operating as a battery tester,
VOLTAGE, the CHARGED and
When a battery % is calculated for
13
•
•