Creda FLORIDA PLUS 설치 및 사용자 설명서 - 페이지 7
{카테고리_이름} Creda FLORIDA PLUS에 대한 설치 및 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Creda FLORIDA PLUS 12 페이지. Electric shower

HOW TO USE YOUR
1. Ensure the electricity and water are turned on to the unit.
2. Your shower has 3 power settings selected by turning
knob "A" (see Diagram 6).
The most popular is "FULL HEAT" indicated by "
your convenience this can be obtained in two positions so
you are always only one step away from maximum power.
There are also options for a "HALF HEAT
"COLD
" shower (see notes 8 and 9).
For this example turn knob "A" to "FULL HEAT"
(either will do) and set knob "C" to "6 o'clock".
3. Press button "B". The water will flow and three lights will
illuminate to indicate that the selected power is "FULL HEAT".
4. Allow about 20 seconds for the temperature of the water to stabilise. It is recommended that
you do not enter the water spray during this period, especially if the shower has just been used.
IF WATER IS TOO COLD
Turn knob "C" anti-clockwise
to "5 o'clock" and continue turning
anti-clockwise until you get the water
temperature of your liking.
Wait 20 seconds after each adjustment
for the water temperature to stablise.
5. Once a temperature setting to your liking
has been achieved, knob "C" will rarely need
adjusting. You must however take into
account required adjustments for variations
of incoming mains water temperature between summer and winter
(see "Effect of Seasonal Incoming Water Temperature Changes" page 10).
6. When you have finished showering, push button "B" only. You have no need to adjust
knobs "A" or "C". Switch off the electricity at the ceiling switch or local isolator.
7. The "HALF HEAT
shower or the option of reduced water flow. This option is mainly for summer usage and if this
is used then knob "C" must be re-adjusted. On this setting two lights will illuminate to indicate
that the selected power rating is "HALF HEAT
8. The "COLD" setting indicated by "
only the "power" light will illuminate to indicate this.
9. Your shower is designed to stabilise temperature changes caused by water pressure
fluctuations (see "Effect of Other Water Devices on Incoming Water Supply" page 10).
10. Note that knob "C" IS NOT A TAP and does not turn the water off.
WARNING: DO NOT SWITCH THE SHOWER ON IF YOU SUSPECT IT OF BEING FROZEN.
WAIT UNTIL YOU ARE SURE IT HAS THAWED OUT.
WARNING: DO NOT OPERATE THE SHOWER IF WATER IS DISCHARGED FROM THE PRESSURE
RELIEF VALVE. MAINTENANCE IS REQUIRED BEFORE THE SHOWER CAN BE USED.
WARNING: CONSIDERATION SHOULD BE GIVEN TO SUPERVISING THE YOUNG, ELDERLY AND
THE INFIRM WHILST THEY USE THIS SHOWER.
FLORIDA PLUS
" setting of knob "A" reduces the power used by the shower giving a cooler
" of knob "A" will supply water without any heating, and
SHOWER (DETAILED)
" and for
" or
IF WATER IS TOO HOT
Turn knob "C" clockwise
to "7 o'clock" and continue turning clockwise
until you get the water temperature of your
liking.
Wait 20 seconds after each adjustment for
the water temperature to stabilise.
If after turning fully clockwise, water is still
too hot, adjust knob "A" to "HALF HEAT
setting and re-adjust as above.
Water flow will be reduced on this setting.
".
7
Diagram 6
"