Digital Equipment DEC WANcontroller 622 문제 해결 - 페이지 5
{카테고리_이름} Digital Equipment DEC WANcontroller 622에 대한 문제 해결을 온라인으로 검색하거나 PDF를 다운로드하세요. Digital Equipment DEC WANcontroller 622 8 페이지.
A
Module Loopback Test
NIC
(a)
Unfasten
screws
(b)
Loopback
connector
1.
Move the NIC
switch down.
4.
Wait until the READY
LED stops flashing
(max. 2 min).
flash
3. If the test passes, LEDs show the RUN state.
If the test fails, LEDs show the FAULT or ATTENTION state.
1. Attach the 50-way loopback
connector to the port to be
tested.
2. Run the module loopback test:
2.
Wait until the hot-
swap LED lights
up (approx. 2 s).
5.
Observe the test
result
on
the
LED display.
no
flash
3.
Move the NIC
switch up.
NOTE
If loading has been
disabled for this slot,
the READY LED will
not stop flashing. To
enable the slot, see
the
manual
DEC
Network Integration
Server
Manage-
ment.
LKG–5727–91I
5