Cisco SGE2000 구성 매뉴얼 - 페이지 35

{카테고리_이름} Cisco SGE2000에 대한 구성 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Cisco SGE2000 46 페이지. Nx-os fabric extender
Cisco SGE2000에 대해서도 마찬가지입니다: 빠른 설치 매뉴얼 (32 페이지), 릴리스 노트 (16 페이지), 데이터시트 (5 페이지), 펌웨어 업그레이드 매뉴얼 (5 페이지), 빠른 시작 매뉴얼 (2 페이지)

Cisco SGE2000 구성 매뉴얼
Configuring the Fabric Extender

Dual-homing of a Server to a FEX with FabricPath

To configure FabricPath interfaces for two Cisco Nexus 7000 switches that are connected with FabricPath,
perform the following tasks on each switch:
• Enable FabricPath on each switch.
• Configure the interfaces that you want to designate as FabricPath interfaces.
• Set the STP priority device to 8192 on all FabricPath Layer 2 gateway devices.
• (Optional) Set the STP domain ID for each of the separate STP domains that are connected to the
FabricPath network.
• (Optional) Configure a FEX switch ID.
To configure FabricPath interfaces, follow these steps:
1 (Optional) Enable FabricPath on each switch.
switch# config terminal
switch(config)# feature fabricpath
switch(config-lldp)# exit
switch(config)#
2 After you enable FabricPath on the switch, configure the specified interface as FabricPath interfaces.
switch(config)# interface ethernet 1/2
switch(config-if)# switchport mode fabricpath
switch(config-if)# exit
switch(config)#
3 Configure the STP priority for all Rapid PVST+ VLANs as 8192.
switch# config terminal
switch(config)# spanning-tree vlan 11-20 priority 8192
switch(config)#
4 Configure the STP priority for all MST instances as 8192.
switch# config terminal
switch(config)# spanning-tree mst 1-5 priority 8192
switch(config)#
5 (Optional) Configure the STP domain ID on each FabricPath Layer 2 gateway switch attached to the
FabricPath network.
switch# config terminal
switch(config)# spanning-tree domain 5
switch(config)
6 (Optional) Configure the FEX switch ID.
See the Cisco Nexus 7000 Series NX-OS Interfaces Configuration Guide for information on configuring
Note
FEX.
Note
FEX VPC+ configurations are only supported on F2 modules.
If you are setting up an initial FEX VPC+ configuration on an F Series module, follow these steps:
a In the VPC domain configuration mode, enable partial DF mode with the fabricpath multicast
OL-25816-02
load-balance command.
Cisco Nexus 2000 Series NX-OS Fabric Extender Software Configuration Guide
Configuration Examples