Install the Hardware
—
A
-48/-60V
20/16A
-48
RTN
Terminal block
cover and
captive screws
C
Cable strain relief
nylon cable tie
Step 2
Loosen the two captive screws that secure
the terminal block cover, as shown in A.
Step 3
Pull the terminal block cover away from
the terminal block, as shown in B.
Step 4
Feed the return (RTN) and –48V wires
through the large hole in the terminal
block cover, as shown in C.
Step 5
Attach a nylon cable tie to secure the
cables to the terminal block cover.
Step 6
Attach the RTN and –48 leads to the
terminal block, as shown in C.
Caution: Do not strain the connection at the terminal block
B
-48/-60V
20/16A
RTN
D
-48/-60V
20/16A
RTN
Ground
terminal
Note
Match the color coding at the DC source.
Typically, green or green/yellow is used for ground,
black is used for RTN, and red or white is used for
–48V.
Step 7
Attach the ground cable to the ground
terminal.
Step 8
Replace the terminal block cover, as
shown in B.
Step 9
Tighten the captive screws on the terminal
block cover, as shown in A.
—
-48
—
-48
7