Troubleshooting
Important
The FSC-400GB is equipped with a single 400 GB drive. Only the Drive 1 Activity LED will be active; the
Drive 2 Activity LED will always be off (None).
The possible states for this LED are described in the following table. If the LED is not green, use the
troubleshooting information also provided to diagnose the problem.
Table 15: FSC Driven Activity LED States
Color
Green
None
None
Checking the LEDs on the SSC
Each SSC is equipped with the following LEDs as shown in the accompanying figure:
• Run/Fail
• Active
• Redundancy
• System Status
• System Service
Description
Files are being transferred to or accessed
from the RAID configuration by the MIO.
There is no RAID activity.
OR
RAID configuration is unavailable.
Card is not receiving power
Checking the LEDs on the SSC
Troubleshooting
None required.
Checking the LEDs on the MIO Card, on
page 3
FSC-400GB is not equipped with a second
SDD. Only the Drive 1 Activity LED will
be active.
Verify that the Run/Fail LED is green. If
so, the card is receiving power and POST
results are positive. If it is off, refer to
Run/Fail LED States, on page 12
troubleshooting information.
Troubleshooting
FSC