Troubleshooting
Figure 3: DPC Status LEDs
The possible states for all of the DPC/UDPC or /DPC2/UDPC2 LEDs are described in the sections that follow.

DPC Run/Fail LED States

The DPC/UDPC or /DPC2/UDPC2 Run/Fail LED indicates the overall status of the card. This LED should
be green for normal operation.
The possible states for this LED are described in the following table. If the LED is not green, use the
troubleshooting information in the table to diagnose the problem.
Table 9: DPC Run/Fail LED States
Color
Green
Blinking Green
Red
Description
Card powered up with no errors detected.
Card is initializing and/or loading software.
Card powered up with error(s) detected.
DPC Run/Fail LED States
Troubleshooting
None needed.
This is normal operation during boot-up.
Errors were detected during the Power On
Self Tests (POSTs). It is likely that the
errors were logged to the system's
command line interface during boot.
Troubleshooting
9