Cisco SCE8000 10 GBE 빠른 시작 매뉴얼 - 페이지 19
{카테고리_이름} Cisco SCE8000 10 GBE에 대한 빠른 시작 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Cisco SCE8000 10 GBE 25 페이지. 10 gbe power supply
Viewing Configurations
When you enter configuration commands, this action immediately affects the SCE platform operation and configuration. The
configuration, referred to as the running-config, is saved in the SCE platform volatile memory and is effective while the SCE
platform is up. After reboot, the SCE platform loads the startup-config, which includes the nondefault configuration that was
saved by the user, into the running-config.
The SCE platform provides commands for:
• Viewing the running configuration with only user-configured (nondefault) values: show running-config
• Viewing the running configuration with all the SCE platform running configuration values, whether default or not: show
running-config all-data
• Viewing the startup configuration: show startup-config
After configuring the SCE platform, you may query for the running configuration using the command show running-config.
At the Cisco SCE8000# prompt, type show running-config. The system shows the running configuration.
Step 1
SCE8000#show running-config
#This is a general configuration file (running-config).
#Created on 12:06:13
#cli-type 1
#version 1
no management-agent notifications notification-list 1417,1418,804,815,1404,1405,1406,1407,1408,400
no management-agent notifications notification-list 402,421,440,441,444,445,446,450,437,457
no management-agent notifications notification-list 3593,3594,3595,10040
snmp-server community "public" ro
RDR-formatter forwarding-mode multicast
RDR-formatter destination 10.56.96.26 port 33000 category number 1 priority 100
RDR-formatter destination 10.56.96.26 port 33000 category number 2 priority 100
RDR-formatter destination 10.56.96.26 port 33000 category number 3 priority 100
RDR-formatter destination 10.56.96.26 port 33000 category number 4 priority 100
interface LineCard 0
connection-mode inline on-failure external-bypass
no silent
no shutdown
attack-filter subscriber-notification ports 80
replace spare-memory code bytes 3145728
interface GigabitEthernet 1/1
ip address 10.56.96.46 255.255.252.0
interface TenGigabitEthernet 3/0/0
bandwidth 10000000 burst-size 50000
global-controller 0 name "Default Global Controller"
interface TenGigabitEthernet 3/1/0
bandwidth 10000000 burst-size 50000
global-controller 0 name "Default Global Controller"
interface TenGigabitEthernet 3/2/0
bandwidth 10000000 burst-size 50000
global-controller 0 name "Default Global Controller"
interface TenGigabitEthernet 3/3/0
bandwidth 10000000 burst-size 50000
global-controller 0 name "Default Global Controller"
exit
ip default-gateway 10.56.96.1
line vty 0 4
exit
management-agent property "com.pcube.management.framework.install.activation.operation" "Install"
management-agent property "com.pcube.management.framework.install.activated.package" "SCA BB"
management-agent property "com.pcube.management.framework.install.activated.version" "3.1.6 build 79"
management-agent property "com.pcube.management.framework.install.activation.date" "Sun May 11 08:44:04
GMT+00:00 2008"
flow-filter partition name "ignore_filter" first-rule 4 num-rules 32
flow-filter partition name "udpPortsToOpenBySw" first-rule 40 num-rules 21
UTC
SUN
May
11
2009
19