Cisco UCS B420 M3 설치 및 서비스 참고 사항 - 페이지 27

{카테고리_이름} Cisco UCS B420 M3에 대한 설치 및 서비스 참고 사항을 온라인으로 검색하거나 PDF를 다운로드하세요. Cisco UCS B420 M3 38 페이지. High performance blade server
Cisco UCS B420 M3에 대해서도 마찬가지입니다: 업그레이드 매뉴얼 (8 페이지)

Cisco UCS B420 M3 설치 및 서비스 참고 사항
• DDR3, 1600 millions of transfers per second (MT/s) across four Channels
• 12 DIMMs per CPU (48 DIMMs total)
• Maximum capacity of 1536 GB (using 32-GB DIMMs)
Performance is less than optimal if the following memory configurations are used:
• Mixing DIMM sizes and densities
• Unevenly populating DIMMs between CPUs
Depending on the application needed, performance loss might or might not be noticeable or measurable.
Installing a Virtual Interface Card Adapter
You must remove the adapter card to service it.
Note
To install a Cisco VIC 1340 or VIC 1240 in the blade server, follow these steps:
Procedure
Step 1
Position the VIC board connector above the motherboard connector and align the captive screw to the standoff post on
the motherboard.
Step 2
Firmly press the VIC board connector into the motherboard connector.
Step 3
Tighten the captive screw.
27