Step 4: View the actions being performed on the Storage > Storage Log tab.
Step 5: The rebuild time depends on the drive capacity. After the rebuild is complete, the physical drive status
changes from Rebuild to Online, and the virtual drive health status is listed as Good. View the Storage > Physical
Drive Info tab. Then view the Storage > Virtual Drive Info tab.
Changing the RAID Level with the WebBIOS Utility
As the amount of data and the number of drives in your system increase, you can use RAID-level migration to
change a virtual drive from one RAID level to another. You do not have to power down or restart the system. When
you migrate a virtual drive, you can keep the same number of drives, or you can add drives. You can use the
WebBIOS configuration utility to migrate the RAID level of an existing virtual drive.
Note:
Although you can apply RAID-level migration at any time, you should do so only when no reboot
operations are occurring. Many operating systems run I/O operations serially (one at a time) during bootup. With
RAID-level migration running, a boot operation may take more than 15 minutes.
Follow the steps presented here to change the RAID level using the WebBIOS configuration utility.
© 2014 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public.