Cisco Catalyst 8200 Series 빠른 시작 매뉴얼 - 페이지 7
{카테고리_이름} Cisco Catalyst 8200 Series에 대한 빠른 시작 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Cisco Catalyst 8200 Series 8 페이지. Installing andupgrading field replaceableunits
Installing and Upgrading Field Replaceable Units
4. Plug in the new M.2 storage module in the same location and secure it with the screws.
Installing and Removing a NIM
These are the steps to install a NIM:
1. Locate the NIM slot on the front panel.
2. Loosen the screws to remove NIM blank cover.
3. Insert the NIM into the slot.
4. Tighten the screws to secure the NIM in the slot.
These are the steps to remove a NIM:
1. If the NIM is up and running, issue the following command to shut down the NIM gracefully before
removing it:
hw-module subslot slot 0/2 stop
Caution
If you do not shut down the NIM gracefully before removing it, the NIM card could get damaged.
2. Locate the NIM slot on the front panel.
3. Loosen the screws that secure the NIM.
4. Gently pull out the NIM from the slot.
1
Securing screws (torque 3.9-5.4 in-lbs)
3
Chassis cutout prevents M.2 installation
in wrong orientation.
Installing and Removing a NIM
2
M.2 module orientation with metal
carrier on top, M.2 module underneath.
Installing and Upgrading Field Replaceable Units
7