Fireplace Installation
unit to the live wire from the
power supply.
• Connect the N and H1 wires
from the unit to the neutral
wire from the power supply.
• Connect the L2 and H2 wires
together, with a wire connec-
tor and leave them discon-
nected from everything.
• Attach the grounding wire to
the cover with the provided
grounding screw. Place wire
in-between screw and lock
washer and tighten (Figure 4).
• Reposition the electrical cover
brackets over the wires and
connectors and attach to fire-
place chassis using the screw
removed in step 1 and step 3.
For 240V Installations
Use three conductor, non-metallic
sheath cable with ground wire
(4 wires total) for the incoming
power supply on fireplace inserts.
CAUTION: Use the appropri-
Figure 4
Hole for
Ground Screw
ate wire to meet local and
national electrical codes for
rated power consumption.
• Connect the L1 wire from the
unit to the L1 wire from the
power supply.
• Connect the L2 wire from the
unit to the L2 wire from the
power supply.
• Connect the N wire from the
unit to the neutral wire from
the power supply.
• Connect the H1 and H2 wires
together, with a wire connec-
tor and leave them discon-
nected from everything.
• Attach the grounding wire to
the cover with the provided
grounding screw. Place wire
in-between screw and lock
washer and tighten (Figure 4).
• Reposition the electrical cover
brackets over the wires and
connectors and attach to fire-
place chassis using the screw
removed in step 1 and step 3.
For Bathroom Use
If this unit is installed in a bath-
room it must be protected by a
GFI receptacle or circuit. If recep-
tacle is used it must be readily
accessible.