N – Power input for +24VDC
L – Power input for -24VDC
IN – Input for load power supply +24VDC.
OUT1 – Output for Motor direction 1.
OUT2 – Output for Motor direction 2.
S1 – External switch 1 control for Motor. (use -24VDC)
S2 – External switch 2 control for Motor. (use -24VDC)
3. Install Nano Shutter to the gang box.
a. Live/Hot wire connection: Connect the Live/Hot wire to the "L" terminal on the Nano Shutter. + Live/Hot on External
Switch input.
b. Neutral wire connection: Connect the Neutral wire to the "N" terminal on the Nano Shutter.
b. Load wire neutral connection (To AC Neutral): Connect the Load/Motor neutral wire to your AC Neutral connection.
c. Load wire motor connection (To Nano Shutter): Connect the 2 Load/Motor wires (Motor direction 1 and Motor
direction 2) to "OUT1" and "OUT2" on Nano Shutter.
d. External/manual Switch connection: Connect 2 18AWG wires to the "S1" and "S2" on the Nano Shutter.
d. External/manual Switch connection: Connect 2 18AWG wires form the 2 terminals on the External/manual Switch to
the Live wire.
Note: This is the physical connection diagram for 120/230VAC power input.