PARTS IDENTIFICATION

2
4
5
3
6
13
12
11
1
Motor housing
2
On/Off switch (red button)
3
Main reservoir pressure gauge
4
Output pressure regulator
5
Outlet tap
6
Output pressure gauge
7
Trolley handle
7
1
8
9
8
Support frame
9
Drain valve
10 Compressed air reservoir
11 Wheel
12 Pressure regulator and cut-out
13 Oil dipstick
10
OPERATING INSTRUCTIONS
Switching the air compressor OFF
To switch the air compressor off,
1.
Close the outlet tap and press down on the on/off button (red button)
located on top of the pressure regulator
2.
Switch off the mains supply and remove the plug.
• You should never leave the compressor air reservoir unattended while
under pressure, as this could be hazardous.
• Always release the pressure from the reservoir when not in use or prior
to storage, as described in 'Draining the reservoir' on page 16.
Removing a tool from the air hose
Always set the pressure regulator to zero before attempting to remove or
1
Press down the on/off switch (red button) located on top of the pressure
regulator.
2
Close the air outlet tap and trigger the equipment (spraygun, air tool etc),
to release air from the air hose BEFORE disconnecting the hose from the
10
machine.
Reset button
This compressor is equipped with a thermal
overload device, which operates as a
safety device to protect the motor.
When the motor overheats for any reason,
the overload cutout automatically cuts the
power thereby preventing damage to the
motor.
Wait around 5 minutes for the motor to cool
and press the reset button.
If you restart the compressor and the
overload cutout activates again, switch off
the compressor, remove the plug from the
mains and have your compressor checked by a qualified service agent.
WARNING!
replace a tool.