General
This Electronic digital meter features a turbine
measurement system, designed for precise
measuring of low viscosity fluids. It is divided into
two using macrogroups:
1. With body made of inconductive plastic
material of light color, designed to be used with
water/urea solution.
2. With body made of conductive plastic material
of dark color (assessed resistance: 50 ohm),
designed to be used with DIESEL FUEL,
WATER and windscreen fluids.
The circuit board can be rotated with respect to
its housing, thus allowing easy display reading in
any position. The circuit board housing, easily
accessible, is enclosed by a plastic cover sealed
through a rubber guard acting as a gasket as well.
The whole unit can be easily removed by
unscrewing the 4 screws securing the circuit board
and the cover.(Fig.2)
Turbine Measurement System
The turbine is placed inside a hole through the
body of 8424, fitted with threaded inlet and outlet.
The body of 8424 is made of a plastic material that
allows several types of threads with relevant
combinations. 8424 has two rubber guards which
are designed to act as gaskets thus reducing the
number of its components.
The liquids compatible with 8424 must be at low
viscosity, namely: Diesel fuel, Water, Water/urea
solution, Kerosene, Windscreen, Petrol.
This document contains confidential information that is the property of Alemite, LLC
671005
and is not to be copied, used, or disclosed to others without express written permission.
Service Guide
Flow Meter
Display
When repositioning the circuit board, make sure
the battery contact cable is not placed above the
circular housing of the bulb.

Operating Modes

Alemite, LLC
167 Roweland Drive, Johnson City, Tennessee 37601
www.alemite.com
©
Copyright
2011 by Alemite, LLC
Figure 1 Flow Meter Model 8424
Figure 1 Flow Meter Model 8424
Figure 1 Flow Meter Model 8424
WARNING
Figure 2 Flow Meter 8424 (Housing Rotated)
8424
SER 8424
Revision (1-11)