SER 8424
The user can choose between two different operating
modes:
1. Normal Mode: Mode with display of Partial and Total
dispensed quantities.
2. Flow Rate Mode: Mode with display of Flow Rate, as
well as Partial dispensed quantity.
The meter features a non-volatile memory for storing
the dispensing data, even in the event of a complete power
break for long periods. The measurement electronics and
the LCD display are fitted in the top part of the 8424 which
remains isolated from the fluid-bath measurement chamber
and sealed from the outside by means of a cover.
LCD Display
The "LCD" of the METER features two numerical
registers and various indications displayed to the user only
when the applicable function so requires.
1
2
3
1. Partial register (5 digits with moving decimal FROM
0.1 to 99999) indicating the volume dispensed since the
reset button was last pressed;
2. Indication of battery charge;
3. Indication of calibration mode;
4. Totals register (6 digits with moving decimal point
FROM 0.1 to 999999), that can indicate two types of
Total: General Total that cannot be reset (TOTAL)
Resettable total (Reset TOTAL)
5. Indication of total multiplication factor (x10/x100)
6. Indication of type of total, (TOTAL/Reset TOTAL);
7. Indication of unit of measurement of Totals:
8. Indication of Flow Rate mode
9. Indication of unit of measurement of Partial:
User Buttons
The 8424 features two buttons (reset and cal) which
individually perform two main functions and, together,
other secondary functions. The main functions performed
are:
Revision (1-11)
9
8
7
4
5
6
1. For the reset key, resetting the partial register and
resettable total (reset total)
2. For the cal key, entering instrument calibration mode.
Used together, the two keys permit entering
configuration mode, useful for changing the units of
measurements and calibration factor.
Battery Housing
The 8424 is powered by two standard type 1.5 V
batteries (size AAA). The battery housing, easily
accessible, is closed by a metal cover sealed through a
rubber guard acting as a gasket. The whole unit can be
easily removed by unscrewing the 4 screws securing the
cover and the guard to the body.
Installation
8424 features a threaded, inline inlet and outlet (1" gas
or NPT male and female). It has been designed to be easily
installed in any position: fixed in-line or mobile on a
dispensing nozzle. In order to improve the life of the
turbine, it is recommended to fit a strainer before the meter
itself.
WARNING
At the female inlets, tighten the couplings at a
max. torque of 55N/m. At the female inlets, tighten
the couplings at a max. torque of 55N/m.
With The Gas-female Inlets, Do Not Use Conical
Threaded Couplings.
Daily Use
The only operations that need to be done for daily use
are partial and/or resettable total register resetting.
Occasionally the meter may need to be configured or
calibrated. To do so, please refer to the relevant sections.
Below are the two typical normal operation displays.
One display page shows the partial and reset total
registers. The other shows the partial and general total.
Switch over from resettable total to general total display is
automatic and tied to phases and times that are in factory
set and cannot be changed.
2
Flow Meter
Alemite, LLC