Army Aviation TCS Series 매뉴얼 - 페이지 11

{카테고리_이름} Army Aviation TCS Series에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Army Aviation TCS Series 19 페이지.

2. Press【MR/CAL】key to display"M-XX"for 1 second and
then display "the accumulated weight value" for 1
second 。
3. Return by itself in weigh mode.
5.3 CLEAR ACCUMULATION FUNCTION
Clear Accumulation Function can be used to clear the
accumulated results and the accumulated value each time.
1. One or more times accumulated operation can be
performed according to item 5.2
2. Press【MC/UNIT】key to display "CLr-M" and return by it
self in weigh mode. After clearing accumulated messages,
next accumulative operation can be performed.
5.4 COUNTING MODE
TCS bench scale has sample counting function.
1. In weighing mode, press【MC/UNIT】key to change in PCS
mode.
2. Put some samples on pan.
3. Press【M+/SMPL】key to display"S- 5"
4. Press【ZERO】key to select 5,10,20,50,100,200,500,1000
circularly.
11