DOF FREEDOM X5 사용자 설명서 - 페이지 15
{카테고리_이름} DOF FREEDOM X5에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. DOF FREEDOM X5 20 페이지. Camera moving model scanner
User manual
Adjusts the amount of projector light. The more red dots you see, the brighter the
❸
projector light. When scanning, please set the red dot to be very subtle on the
abutment area. It is more convenient to use the Auto Light function, but recommended
to manually adjust the brightness depending on the model characteristics. When you
deselect the Auto Light icon, it changes to manual mode.
28
Scanning Instructions
Base Model Scan
4
Position the model correctly on the scanner and proceed with scanning.
❶
Click the scan button to start scanning.
❷
During Base Scan Stage, the teeth surrounding the abutment teeth are scanned.
❸
The abutment scan is performed after the base scan is completed.
The base scan is used to distinguish the adjacent teeth from the abutment teeth after
scanning the abutment teeth.
In the Base Scan Stage, check whether the adjacent tooth contact surface has been
❹
scanned properly, If insufficient, please perform additional scans.
Click!
Scanning Instructions
29