Baumer NE210 Operating Instructions Manual - Page 30

Browse online or download pdf Operating Instructions Manual for Cash Counter Baumer NE210. Baumer NE210 44 pages. Electronic preset electronic preset counter

Baumer NE210 Operating Instructions Manual
NE210
To be used
- If the pulse generator is notsupplied by
the sensor powersupply from the counter.
- If the pulse generator has a push-pull or
PNP output stage.
- If several counters are triggered in
parallel by a single pulse generator.
- If the pulse generator has an NPN output
stage.
- In conjunction with a max. 24 VAC power
supply.
30
Sensor signal
PNP , triggered by a plus
signal.
B
NPN, triggered by a
minus signal.
B
Alternating voltage
input: 7 , 8 and 9
trggered by
max. 24 VAC.
Electrical isolation is provided for instruments with an AC voltage
supply and a relay output without electronic signal output in the case
of an external sensor supply.
www.baumer.com
Terminal assignment
11 and 12
E
13 12 11 10 9
K
11 and 13
K
13 12 11 10 9
E
13 12
8
7
8
7
11
9
8
7
10