5 Water connection

All water intake connections to the machine should be fitted with manual shut-off valves and filters, to facilitate instal-
lation and servicing.
Water pipes and hoses should be flushed clean before installation.
The machine shall be connected with new water hoses. Re-used water hoses must not be used.
Hoses are to be of an approved type and grade and comply with IEC 61770.
After installation hoses must hang in gentle arcs.
All connectors present on the machine must be connected. The table shows the possible connection options, which
will depend on the water types to be connected to the machine. Information is also available on the panel above the
connections.
1
2
Remove the three plastic covers (A).
Note!
For unheated machines with Lagoon Advanced Care programs, the programs requires pre heating (25℃) for
the cold water valves.
Note!
The inlet temperature for cold water must not be higher than 25℃. If so, a water cooling system must be
installed.
Installation manual
Water type
• Cold and hot
3
A
Water connection
1. Cold
2. Hot
3. Cold (for detergent dispenser) / Hot
15
fig.7811B