Anden A200V1 Installation And Operating Instructions Manual - Page 7
Browse online or download pdf Installation And Operating Instructions Manual for Dehumidifier Anden A200V1. Anden A200V1 12 pages.
WIRING INSTRUCTIONS
1. Disconnect electrical service at the main fuse or circuit breaker box.
2. Install an electrical disconnect to the line service, located per local and national standard.
3. Remove the electrical service panel from the dehumidifier. See FIGURE 13.
4. Route the service cable through one of the holes in the top of the dehumidifier. USE ONLY COPPER SUPPLY WIRES.
5. Secure the cable/conduit to the dehumidifier using fittings/connectors approved for the type of cable/conduit used.
6. Connect the ground wire of the service cable to the ground lug in the electrical service box. See FIGURE 14.
7. Connect the line voltage wires of the service cable to the L1 and L2 terminals. See FIGURE 14.
8. Reattach the electrical service panel.
9. Restore electrical service at the main fuse or circuit breaker box.
FIGURE 13 – ELECTRICAL CABINET (SERVICE PANEL REMOVED)
ELECTRICAL SERVICE OPENINGS
ELECTRICAL
COMPARTMENT
FIGURE 14 – POWER WIRING
2-POSITION POWER TERMINAL BLOCK AND GROUND LUG
LOCATED IN DEHUMIDIFIER ELECTRICAL PANEL. INSERT WIRE
INTO OPENING AND SECURE USING THE TERMINAL SCREWS.
90-2328
GND
L1
L2
7