DURKOPP ADLER 867 Additional Instructions - Page 13

Browse online or download pdf Additional Instructions for Sewing Machine Accessories DURKOPP ADLER 867. DURKOPP ADLER 867 20 pages. Remaining thread monitor
Also for DURKOPP ADLER 867: Instructions Manual (16 pages), Instructions (4 pages), Instructions Manual (16 pages), Instructions Manual (8 pages), Additional Instructions (18 pages)

DURKOPP ADLER 867 Additional Instructions
Assembling the remaining thread monitor
Fig. 7: Connecting the remaining thread monitor on PREMIUM machines (2)
(1) - Circuit board
(2) - Magnet valve
3. Insert the magnet valve (2) into socket X16 on the circuit board (1).
4. Assemble the circuit board (1).
5. Tighten the connection plate (4) on the holder (3).
Fig. 8: Connecting the remaining thread monitor on PREMIUM machines (3)
(5) - Compressed air maintenance unit
(6) - Hose
Additional Instructions 867/867-M PREMIUM - 00.0 - 07/2018
If socket X16 is already occupied, use socket X17 or socket X18.
(3) - Holder
(4) - Connection plate
(7) - Valve