6. Assemble the compressed air maintenance unit (5) to the stand.
7. Use an R 1/4" hose coupling to connect the connection hose to
8. Set the operating pressure to 6 bar.
9. Connect the hose (6) to the valve (7).

2.3 Setting the remaining thread monitor electrically

Important
The remaining thread monitor is delivered with a basic setting.
As a rule, the sensitivity of the residual thread monitor does NOT have
to be set!
The pre-set sensitivity of the remaining thread monitor may only be
changed if the remaining thread monitor is not working properly.
Fig. 9: Setting the remaining thread monitor electrically
(1) - Plug connection light barrier,
(2) - Plug connection light barrier,
(3) - Plug connection inputs and outputs
After the machine has been switched on and before it starts sewing, the
remaining thread monitor is in setting mode.
To set the remaining thread monitor:
1. Switch on the machine.
2. Insert an empty bobbin into the hook.
3. Turn the hook to a position that the light beam falls through the slot in
4. Set the potentiometer (5) or (7) to the highest sensitivity.
12
the compressed air supply.
right hook
left hook
of the control
the hook housing onto the bobbin.
To do this, turn the potentiometer clockwise.
Assembling the remaining thread monitor
(4) - Plug connection switched output
(5) - Potentiometer left hook
(6) - LED
(7) - Potentiometer right hook
(8) - Plug connection auxiliary output