Datalogic S70 Quick Start Manual - Page 8
Browse online or download pdf Quick Start Manual for Accessories Datalogic S70. Datalogic S70 10 pages. Advanced sensor with dual digital displays for use with plastic and glass fiber optic assemblies
Also for Datalogic S70: Manual (18 pages)
- Light SET
•
Sets a threshold a programmable % offset below the presented condition
•
Changes output state on any condition darker than the threshold condition
•
Threshold can be adjusted using "+" and "-" Navigation key (Manual Adjust)
•
Recommended for applications where only one condition is known, for example a stable light background with varying darker
targets
•
See
Program Mode
A single sensing condition is presented, and the sensor positions a threshold a programmable % offset below the presented condition. When
a condition darker than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO setting.
- Dark SET
•
Sets a threshold a programmable % offset above the presented condition
•
Any condition lighter than the threshold condition causes the output to change state
•
Threshold can be adjusted using "+" and "-" Navigation key (Manual Adjust)
•
Recommended for applications where only one condition is known, for example a stable dark background with varying lighter
targets
•
See
Program Mode
NOTE: Offset Percent MUST be programmed to Minimum Offset to accept conditions of no signal (0 counts).
A single sensing condition is presented, and the sensor positions a threshold a programmable % offset above the presented condition.
When a condition lighter than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO setting.
- Calibration SET
•
Sets a threshold exactly at the presented condition
•
Threshold can be adjusted using "+" and "-" Navigation key (Manual Adjust)
A single sensing condition is presented, and the sensor positions a threshold exactly at the presented condition. When a condition lighter
than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO setting.
for programming the Offset Percent setting
Light SET (Light Operate shown)
on page 5 for programming the Offset Percent setting
Calibration SET (Light Operate shown)
Dark SET (Light Operate shown)
8