- Light SET
•
Sets a threshold a programmable % offset below the presented condition
•
Changes output state on any condition darker than the threshold condition
•
Threshold can be adjusted using "+" and "-" Navigation key (Manual Adjust)
•
Recommended for applications where only one condition is known, for example a stable light background with varying darker
targets
•
See
Program Mode
A single sensing condition is presented, and the sensor positions a threshold a programmable % offset below the presented condition. When
a condition darker than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO setting.
- Dark SET
•
Sets a threshold a programmable % offset above the presented condition
•
Any condition lighter than the threshold condition causes the output to change state
•
Threshold can be adjusted using "+" and "-" Navigation key (Manual Adjust)
•
Recommended for applications where only one condition is known, for example a stable dark background with varying lighter
targets
•
See
Program Mode
NOTE: Offset Percent MUST be programmed to Minimum Offset to accept conditions of no signal (0 counts).
A single sensing condition is presented, and the sensor positions a threshold a programmable % offset above the presented condition.
When a condition lighter than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO setting.
- Calibration SET
•
Sets a threshold exactly at the presented condition
•
Threshold can be adjusted using "+" and "-" Navigation key (Manual Adjust)
A single sensing condition is presented, and the sensor positions a threshold exactly at the presented condition. When a condition lighter
than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO setting.
for programming the Offset Percent setting
Light SET (Light Operate shown)
on page 5 for programming the Offset Percent setting
Calibration SET (Light Operate shown)
Dark SET (Light Operate shown)