b. The battery somehow has becomes disconnected from
the charger while it was in the charge process.
c. If the battery was accidentally connected to the output
connector in reverse polarity.
In any case, recheck to make sure the battery is connected to
the output connector properly as explained above. Check to
make sure the charge lead is making good contact with the
charger's output connector, and with the battery to be
charged, and that proper polarity is being observed.
The Peak 400 charger uses solid-state and fused
circuitries to protect against potential damage which could
be caused by short-circuit or reverse polarity conditions.
Reverse Input Polarity: If input power to the charger is
connected in reverse polarity, the charger will be protected from
damage by blowing the external 7.5A fuse, but will be protected
from damage. Re-check all input connections and the power
source to ensure the proper power and polarities are observed.
Battery Condition Pre-Check: Any time a command is given
to begin charging a battery, the charger will check the condition
of the battery and determine if it is suitable for charging. If an
error exists on the output, the LEDs will flash red and green
simultaneously to note the error.This can occur when a battery
is connected to the output in reverse polarity, or if the charger
does not recognize a solid electrical connection to the battery
on the output. The charger will be protected from damage in
either case. Make sure the battery is solidly connected to the
output in proper polarity.
PR
O
TECTION FEA
PR
O
TECTION FEA
TURES
TURES