The Peak 400 will automatically supply trickle charge current
to NiCd and NiMH batteries immediately after quick charge
has ended.
The trickle charge current level is determined by the setting of
the fast charge current switch. The approximate trickle charge
rates are as follows:
Fast charge setting
The Peak 400 charger will indicate that fast charge has ended
and trickle charge has begun by the LED flashing only under
the selected battery type (i.e. NiCd or NiMH). The charger will
remain in the trickle charge state until the battery is removed
from the charger, the 3 hour time limit has been reached, or
another input command is given to the charger.
The Peak 400 charger utilizes a unique and handy safety
feature to warn if problems exist when attempting to quick
charge a battery. If a charge's LEDs flash red and green
simultaneously, it is an indication that one of 3 potential
problems exists, as follows:
a. The battery was not properly connected to the output
before the charge button was pressed.