ADEMCO Vista 4120 Installation Instructions Manual - Page 15
Browse online or download pdf Installation Instructions Manual for Security System ADEMCO Vista 4120. ADEMCO Vista 4120 18 pages.
TESTING THE SYSTEM
After installation is completed. the Security System should be
carefullv tested.
1.
2.
With the System in the disarmed state, check that all zones
are intact. lf NOT READY is displayed, press the ['I key to
display the faulted zone(s). Restore faulted zone(s) if
necessary, so that READY is displayed. Fault and restore
every sensor indiiidually to assure that it is being monitored
by the system.
Enter the wcurlty
code and press the TEST key. The
external sounder (ff used) shoukf sound for 3 seconds and
then turn off and a test report should be transmitted (if
programmed) to the Central Station. lf the badtup hattey is
discharged or missing, the external sounder will not turn on
and a LOW BATTERY report will be transmitted instead of a
TEST report.
A message will he sent to the central statbn during the folbwing
test. Notify the central station that a test will be in progress.
Arm the system and fautt one or more zones. Silence alarm
sounder(s) each time by entering the code and pressing
OFF. Check Entry/Exit delay zones.
Check the keypad-initiated alarms by pressing the Panic
key pairs-[1 and 18) and/or p] and [8& If the system has
been programmed for audible emergency, the console will
emil a bud, steady alarm sound, and AlARM and 99 will be
diiyed
for 11 and [a (if p] and [rr) are pressed, 96 will
be displayed). Silence the atarm hy entering wcurlty code
end pressing OFF.
II the system has been programmed for silent em-ergency.
there will be no audible alarms or displays, but a report will
be sent to the central station.
Notify the central station that all tests are finished, and
verify results with them.
NOM:
0
ffthabattarystandbycapackyisexceadedduringanAC
power failwe. tha 4120 will automatically shut itself off so
that lt can retain 6s armed state (OFF, AWAY, STAY,
etc.). When AC power is restored, the 4120 will assume
its armed status prior to the AC power interruption.
I
TO THE INSTALLER
Rag&r mabtenanoa and lnsp&in
(at feast annually) by the
instafler and frequent tasting by the usar am vital to continuous
satisfsctory operation of any alarm system.
The installer should assume the responsibility of developing
snd offering a regular maintenance program to the user as well
as acquainting the user with the proper operation and
limitations of the alarm system and its component parts.
Recommendations must be included for a specific program of
frequent testing (at least weakly) to insure the system's proper
operatbn at all times.
SPECIFICATIONS
4120
SECURI'IY CONTROL
1. PhysIcal:
12-Vl'(318 mm) W.
14-12 (388 mm) Ii,
3' (76 mm) D
2. Ebctrfcal
VOLTAGE INPUT: 16.8VAC (from plug-in 26VA transfor-
mer, Adema, No. 132fm2). ln Canadian instal-
latbns. No. 1321 CN must be used.
RECHARGEABLE BACK-UP BATTERY: 12VDC. 4AH
(Gel or starved lead-acid type)
ALARM ST)UNfER: x)-13.8V. 2.8 Amp output (360 mA
max. on alarm for a UL instakatiin).
I
OUTPUT: Can drive 12V motor driven hells (100 mA
each) - AMSECC MSB16G or ABE1 031. Do not
use solenoid operated hells.
Can driie one 7tI2 or two 702 (series connected)
self-contained 29-watt sirens. Do not connect two
702s in parallel.
AUXIUARY POWER OUT-PUT:X)&13.8V DC, XI0 mA
max. for non-UL instalfati~. 400 mA max. for UL
I
installations.
STANDBY TIME: 4 HRS. with Auxiliary bad d 5oomA'
'Using 4 AH Battery
3. Communlcatkn:
FORMATS SUPPORTED:
Ademco Bxpresa, '10 char-acterslsec, DTMF (Touoh-
lone) Data Tones, 14M)I 2300 Hz ACK, 1400 Hz
KISSOFF.
Ademoo Low Speed, 10 pulseslsec, 1900 Hz Data
Tone, 1400 Hz ACW KISS-OFF.
RADIONICS. 20 pulses/ sec. 1800 Hz Data Tone, 2300
Hz ACKMISSDFF reports O-8, B-F).
Line Seize: Double Pole
Ringer Equivalence: 0.78
FCC Registration No.: AC 398U-68192-AL-E.
4127 REMOTE CONSOLE
1. Physfcal:
6-~(l43mm) W
44lrtQMmm) H
2. Elactrlcal:
7&= (22mm)D
Voltage Input: 12V DC
Current Drain: 20 mA
3. Interface Wlrlng:
RED: 12V DC input (+) aux pwr
GREEN: Data In
YELLOW: Data Out
BLACK: Ground
5330 REMOTE CONSOLE
1. Phyalcsl: 7-314yf43mm)W
67116'~%tnn)H
1 114' (32nxn)D
2 Ebctrlcal:
Voltage Input: 12V DC
Current Drain: 106 mA
3. lntertace Wlrlng:
RED: 12V DC input (+) aux pwr
GREEN: Data In
YELLOW Data Gut
BLACK: Ground
4137 REMOTE CONSOLE
1. physlcsl:
8-X. Ql3mm)W
4314' (12mm) H,
2. Electrkal:
l-lfia
(28mm)D
Voltage Input: 12V DC
Current Drain: 60 mA
3. Interface Wlrlng:
RED: 12V DC input (+) aux pwr
BLUE: Not Used
GREEN: Data ln
YELLOW: Data Out
BLACK: Ground
13