CAUTION
Check there are no hidden cables or
pipes before drilling holes for wall plugs.
Exercise great care when using power
tools near water. The use of a residual
current device (RCD) is recommended.
1. Establish position for the
riser rail, and mark the wall for
the lower mounting bracket.
Make allowances for the tallest
person likely to use the shower
regularly.
2. Use a No 10/5.5mm masonry
drill to make a hole 35mm deep,
and fit the wall plug.
(NB some
wall constructions may require the
use of alternative types of wall
fixings).
Screw the lower bracket
base to the wall.
3. Locate the crimped end of
the riser rail (Figure 4) into the
mounting bracket, then fit the
upper bracket. Ensure the rail is
vertical, then mark the wall for
the fixing.
4. The crimped end of the riser
rail.
NOTE If it is necessary to
shorten the rail, use a junior
hacksaw to cut the excess material
from the plain end of the rail.
5. The three components that
comprise the Handset Height
Adjuster assembly are
produced with alphabetical 'A's
and 'B's moulded into the end
section of each part. Simply just
match the letter identification of each part with
the central piece i.e. 'A' to 'A' and 'B' to 'B' for
correct assembly.
6. With the showerhead height
adjuster lever set a 3 o'clock
and the showerhead holder in
the upright position, slide the
assembly onto the rail. Tighten
to the rail by turning the lever.
7. To lock the Handset Height
Adjuster at your chosen position
on the rail. Turn the lever up
right. This action is also used for
holding the showerhead at the
angle required.
8. Re-assemble the rail and
screw the upper mounting
bracket in place.
9. Slide the end cap onto the
mounting brackets.
10. Snap the soap dish onto the
rail below the holder assembly.
11. Slide soap dish down the
rail to required position.
12. Firmly attach flexible hose to
the showerhead making sure
sealing washer is in place.
NOTE the adjustable slider grips the
conical end of the hose, not the
handle of the showerhead.
Maintenance:
Clean regularly with a non-abrasive liquid
bathroom cleaner.
14
SECTION

OPERATING THE SHOWER

IMPORTANT: Ensure the commissioning
procedure has been carried out.
select a larger cable size.
23. In the majority of installations, the
cable will unavoidably be placed in
one or more of the above
conditions. This being so, it is
strongly recommended to use a
minimum of 10mm cabling
throughout the shower installation.
24. In any event, it is essential that
Individual site conditions are assessed
by a competent electrician in order to
Determine
6
SECTION

WATER REQUIREMENTS

The installation must be in accordance
with Water Regulations / Byelaws.
WARNING: Under no circumstances
must this Aqua 9000 XP pumped
shower be connected directly to the
mains water supply.
To ensure activation of the heating
elements, the shower must be connected
to a Cold water supply which is gravity fed
from a static Cold water storage cistern
with a minimum capacity of 114 litres
(25 galls).
There must be a maximum head of water
of 10 metres (33ft) and a minimum head
of 8 cm (3") as measured between the
Bottom of the cistern and the top of the
shower unit. There must be no other Cold
water draw offs between the cistern and
the unit and the pipe must not supply
water to any other tap or fitting at a lower
level.
NOTE: The supply pipe from the cistern
should be on the opposite side to the float
operated valve to prevent air being drawn
into the pipe when the cistern is filling.
If it is intended to operate the shower in
hard water areas (above 200 ppm
temporary hardness) a scale inhibitor
should be fitted.
Fig.2 shows a typical system layout. Do
not use jointing compounds on any pipe
fittings for the installation.
7
SECTION

SITING OF THE SHOWER

WARNING: The shower must not be
positioned where it will be subjected to
freezing conditions.
FOR EASE OF SERVICING, THE UNIT
MUST ALWAYS BE MOUNTED ON THE
SURFACE OF TILED WALLS. NEVER
TILE UP TO THE UNIT.
Refer to Fig.3 for correct siting of the
shower. This product is splash-proof rated
and is approved for use in shower
cubicles and over baths.
However, do not install the unit in a
Position where the sprayhead will
consistently direct water over it.
The shower unit MUST be positioned
vertically.
Fig.2