DynaQuip WaterCop Classic Owner's Manual & Installation Manual - Page 6

Browse online or download pdf Owner's Manual & Installation Manual for Measuring Instruments DynaQuip WaterCop Classic. DynaQuip WaterCop Classic 20 pages.

Local electrical and plumbing codes should be consulted to ensure that the
installation is in complete compliance. (See Installation section for details.)
Notice: WaterCop® should be installed downstream of existing shut-off valves and
pressure reducers . Install 18" downstream from existing indoor water meters to allow
for future meter maintenance .

Placement of Wireless Sensors

Each WaterCop® Classic System can support an unlimited number of wireless
leak sensors . Additional sensors may be added at any time . A sensor consists of a
transmitter (a rectangular box) and a sensor probe (a small disc at the end of the wire,
with two short gold prongs protruding from one side) . Leak sensors should be placed
in locations where leaks are most likely to occur .

Suggested Locations

Washing Machines
Toilets
Ice Makers/Refrigerators
Dishwashers
Automatic Humidifiers
Kitchen Sinks
Bathroom Sinks
Water Heaters
Pipes that are prone to freezing (freeze
sensors are also available)
WARNING:
sprinkler systems.
The transmitter in the leak sensors and the
receiver in the WaterCop® communicate by
radio frequency . The smaller the distance
between them, the stronger the signal will be . The maximum transmission distance
is somewhat dependent upon the building layout and type of construction, but will
be in the 150'–200' range . The transmitter (attached to the sensor) must be kept dry .
It is NOT splash proof . Sensors should never be placed outdoors . The sensor probe
detects the water from a leak and is completely waterproof .
6
Do not use on fire