SETTINGS AND ADJUSTMENTS
AP3000 by activTek can be turned on or off and adjusted
using the included remote .
If you are operating your central heating and
air conditioning fan or other ventilation system
continuously, set the coverage up to the total
ventilated indoor area. Otherwise, set the coverage up
to the size of the room. Do not exceed the size of the
ventilated indoor area when setting the purifier level.
Functions on Unit and Remote
Power (standby) Turns the unit ON and OFF.
Reminder Reset (control panel only)
Clears the maintenance reminders after performing
routine maintenance.
Functions on Remote Only
Fan Up/Fan Down Adjusts the five speed fan.
Away Mode
When the AP3000 is switched to the "Away Mode," the
Corona Discharge Ozone Plate is operated at maximum
output, which is 125% of the 3,000 square foot setting.
This mode is to be used only in unoccupied spaces; all
humans and pets should be removed from the area during
operation and for one hour after treatment completes or
until the ozone has sufficiently dissipated. For optimal
results, use the "Away Mode" to treat individual rooms
where the square footage is under 500 square feet, thereby
allowing the ozone level to sufficiently rise to treat the area
in the 2, 4, 6 or 8 hour programmed setting.
Normal Mode
When the AP3000 is operated in the "Normal Mode,"
ActivePure (RCI) Cell produces is a low level of Hydrogen
Peroxide gas (H2O2) and Super Oxides (O2-), as well as
positive and negative ionization which forms Hydroxyls.
In "Normal Mode", Ozone Free models will not produce
ozone, while Standard Cell models will produce very low
levels.
High Mode
When the AP3000 is switched to the "High Mode," the
Corona Discharge Ozone Plate becomes operational,
producing a low level of ozone based upon the area being
treated in square feet. The AP3000 is designed to produce
.03 to .045 parts per million (ppm) of ozone when the
square footage setting is equal to the ventilated area.
Purifier Up/Purifier Down (High Mode only)
Works when unit is in High Mode to set the purifier level for
the indoor area. The level is indicated by both a horizontal
bar graph and square footage (U.S. models) or square
meters (international models). The unit will switch to Normal
Mode, if the PURIFIER DOWN button is pressed when the
square footage is set to 250 ft
Display FT2 / M2 (remote control only)
Changes the purifier coverage shown on the LCD screen
from square feet to square meters.
*Please note: "unoccupied areas" includes pets. Some
pets, like humans, may experience adverse reactions from
exposure to increased levels of ozone and should not be
present during Away Mode operation.
(23 m
).
2
2
Power ON/OFF
Power ON/OFF
Fan UP
Fan
DOWN
Normal/
High

LCD DISPLAY

The LCD Screen is used to display all current settings (see
page 4) as well as any maintenance reminders .
Fan Speed
Purifier Setting
Reminders
(normally blank - display will flash and reminders
appear here when unit needs maintenance)
LCD SCREEN BACKLIGHT
As adjustments are being made, the LCD screen backlight
will brighten and the settings on the screen will change .
After 3 seconds without change, the backlight will return
to normal .
If a maintenance reminder or a service reminder
appears, the backlight will brighten and constantly flash
until the Reminder Reset button is pressed or the service
problem is corrected.
A P 3 0 0 0
Reminder
Reset
Display FT
/M
2
2
Purifier
UP
Purifier
DOWN
Away Mode
ON/SET/OFF
Battery
compartment
(2 AAA)
Purifier Coverage