Autonics LSE-4A5R2 Product Manual - Page 5

Browse online or download pdf Product Manual for Security Sensors Autonics LSE-4A5R2. Autonics LSE-4A5R2 5 pages. 2d laser scanners
Also for Autonics LSE-4A5R2: Manual (12 pages)

Checking SV
> 9 > Keys for entering each function
The setting value can be checked through the remote controller and the indicator on
the laser scanner for each function.
Theindicator flashes as much as the value of the numeric keys. For more detailed
setting value, refer to Function Setting: Remote Control.
Function
Entering Key
Sensor position
Pos.
Activated channel (s)
Ch
01)
Monitoring zone
W or H > 0 > Ch No.
02)
Concentrated
W or H > 1 > Ch No.
monitoring zone
Sensitivity level
Level
Minimum size of the
Size
scanning target
Monitoring time
Time
Output
RST > 4
01)  Activated Ch1, Ch3 and not activated Ch2, Ch4
+
(flash once) >
+
+
+
(flash twice) >
02)  When checking the height after setting as W 3.4 × H 4.9 m
+
(flash 4 times) >
+
+
+

Troubleshooting

Check the normal operation status of laser scanner periodically.
Error
Causes
Supply the power voltage.
Power indicator
Wrong polarity connection of power
(
, green) OFF
supply
Voltage error
Error indicator
(
, orange)
Temperature error
flashing
Inside error
Detection by external environment
(snow, rain, or hail, etc.)
Relay output
There is the equipment which
is ON without
generates strong magnetic force
objects within
or high frequency noise (motor,
teaching area
generator, or power cable, etc.) near
the laser scanner.
Laser scanner
The batteries' life cycle of the
does not react
remote control is over.
for remote
Wrong direction control of the
control
remote control
operation.
After pressing
the
key of
Password incorrect.
remote control,
the setting is
not available.
LAN connector connection error
atLidar (PC
program)
IP address is not same.
and the laser
scanner does
IP address of the laser scanner and
not connected.
wireless router is same.
Indicator
+
(flash)
Channels'
+
(flash)
Between Ch
+
+
+
(flash once)
Integer value
+
(flash)
Decimal point
+
+
+
(flash once)
Decimal value
+
(flash)
Channels'
+
(flash)
+
(flash)
+
(flash)
+
(flash)
+
(flash)
+
(flash once)
+
+
+
(flash once)
(flash once) >
+
(flash 9 times)
Troubleshooting
Check the rated power supply.
Check the Connection diagram when
wiring the unit.
Use the unit within the rated voltage.
Use the unit within the specified
ambient temperature.
Contact the seller.
Change the settings: sensitivity level,
scanning target size, monitoring time.
Install the laser scanner away from the
equipment which generates strong
magnetic force or high frequency
noise.
Change the batteries.
Operate the remote control towards
the near laser scanner.
Turn OFF the power and re-supply the
power, the password is available to
reset.
Contact the seller.
Check the PC and LAN connector
connection part.
Check the IP address of the laser
scanner and the user PC.
Set the wireless network (Wifi) to
"Disable" in the network settings of the
Windows operating system.
18, Bansong-ro 513Beon-gil, Haeundae-gu, Busan, Republic of Korea, 48002
www.autonics.com | +82-2-2048-1577 | [email protected]