• Apply the drilling template to the inside wall of the wall unit on the
right and left sides, and mark out and predrill Ø 2 mm mounting
holes as well as 2 x Ø 6 mm - 5 mm depth holes for the mounting
claws (installation aids).
• Unscrew the ventilation grill mounted on the appliance (1 screw),
apply the exhaust air union prepared to the required exhaust air
diameter, and twist it to the right to its fullest extent (so that it is
retained).
• Fully withdraw the vapour catcher of the hood.
• Important: Detach and insert the grease filters only when the
vapour catcher is fully withdrawn.
Remove the grease filters. First remove the rear and then the front
grease filter.
• For 19 mm side walls, the spacer discs clipped in on the appliance
body must be taken out. Mount the hood with 4 or 6 x Ø 4 mm
screws. Fig. 7.
Fig. 7
• Insert the hood in the furniture housing and engage both mounting
claws (installation aids) on the right and left sides in the side wall
of the wall unit and firmly hold the hood for further mounting.
Then fix the hood with the 4 or 6 x Ø 4 mm screws supplied.
• Refit the grease filters. Push-in the vapour catcher.