Dell S4148-ON Configuration Manual - Page 12

Browse online or download pdf Configuration Manual for Switch Dell S4148-ON. Dell S4148-ON 19 pages. Dell emc sc series sans

Dell S4148-ON Configuration Manual

Configure Data Center Bridging (DCB) (optional)

3
Configure Data Center Bridging (DCB) (optional)
To enable DCB mode on the switch, use the commands in this section.
Note: Complete the switch configuration steps in section 2 before configuring the switch for DCB mode.
Note: DCB switch configuration is applicable only for environments with DCB-capable SC Series arrays.
3.1

Disable iSCSI

OS10# configure terminal
OS10(config)# no iscsi enable
OS10(config)# no iscsi session-monitoring enable
3.2

Disable 802.3x flowcontrol on all ports

OS10# configure terminal
OS10(config)# interface range ethernet 1/1/1–1/1/54
OS10(conf-range-eth1/1/1-1/1/54)# no flowcontrol receive
OS10(conf-range-eth1/1/1-1/1/54)# no flowcontrol transmit
OS10(conf-range-eth1/1/1-1/1/54)# exit
OS10(config)#
3.3

Enable DCB

OS10(config)# dcbx enable
3.4

Create tagged VLAN for all ports and port-channels

Note: You must supply a VLAN ID. The valid range is 2-4093.
The following commands configure a single VLAN ID. If desired, multiple VLAN IDs can be created on the
switch and assigned to ports.
OS10(config)# interface vlan <vlan-id>
OS10(conf-if-vl-<vlan-id>)# mtu 9216
OS10(conf-if-vl-<vlan-id>)# no shutdown
OS10(conf-if-vl-<vlan-id>)# exit
12 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell EMC SC Series SANs | SCG3704