Also for HP Xw460c - ProLiant - Blade Workstation: Implementation Manual (35 pages), Error Prevention Manual (12 pages), Technical White Paper (12 pages), Firmware Update (9 pages), Installation Manual (2 pages), Frequently Asked Questions Manual (14 pages), Setup Poster (9 pages), Installation Manual (33 pages), Management Manual (28 pages), Hardware Manual (23 pages), Overview (35 pages), Optimization Manual (13 pages), Limited Warranty (10 pages), Installation Instructions Manual (10 pages), Installation Instructions Manual (8 pages), Installation Instructions (4 pages), Installation Instructions (2 pages)

HP Xw460c - ProLiant - Blade Workstation User Manual
HP BIOS Serial Console/EMS Support
Settings and Configuration
In This Section
.........................................................................................................................15
Support............................................................................................................17

RBSU and BIOS Serial Console Configuration

BIOS Serial Console supports console redirection of POST error messages and
configuration utilities and is disabled in the ROM by default. EMS support is
enabled in the OS by default, but also requires system ROM support. This section
takes you through RBSU configuration, basic OS initialization, and terminal
emulation for console redirection.
RBSU displays and modifies the system configuration settings of a server. The
figures in this section show settings for BIOS Serial Console options on the
RBSU menu. Except for the following figure, these screens are shown with
ANSI emulation.
Press the Enter key while BIOS Serial Console is selected on the RBSU main
menu to display the options.
....................................................................................................................15
.......................................................................................17
Services................................................................................................18
.....................................................................................19
NOTE: On some newer servers, the BIOS Serial Console default will
be AUTO instead of disabled. During the boot process, the server will
check for the presence of a VT100 compatible client running at 9600
Baud connected to the server and automatically will enable the BIOS
Serial Console for that boot if one is found. This eliminates the need to
run RBSU with a local keyboard and monitor attached to enable the
BIOS Serial Console feature.