23. Key Pressed 2 times – value of SWITCH ON command sent to
3rd association group
This parameter defines value of SWITCh On command sent to devices
in 3rd association group after a double click.
Available settings: 1-255 - sent value
Default setting:
24. Key Pressed 3 times – command sent to 3rd association group
This parameter defines commands sent to devices associated in 3rd
association group after a triple click.
Available settings: 0 - no action
Default setting:
25. Key Pressed 3 times – value of SWITCH ON command sent to
3rd association group
This parameter defines value of SWITCh On command sent to devices
in 3rd association group after a triple click.
Available settings: 1-255 - sent value
Default setting:
29. Key Held Down – command sent to 3rd association group
This parameter defines commands sent to devices associated in 3rd
association group after holding the button down.
Available settings: 0 - no action
Default setting:
30. Alarm frame triggers
i
NOTE
Parameter determines which actions result in sending alarm frames
values
of
parame-
to 4th association group.
ter 30 may be com-
Available settings: 1 - Key Pressed 1 time
bined,
e.g.
1+2=3
means
that
alarm
frames will be sent
after pressing the but-
ton once or twice.
Default setting:
ADvAnCED PARAMETERS
99
Parameter size:
2 [bytes]
1 - SWITCh On
2 - SWITCh OFF
3 - SWITCh On/OFF – alternately
0
Parameter size:
1 [byte]
255
Parameter size:
2 [bytes]
1 - START LEvEL ChAnGE uP (brightening)
2 - START LEvEL ChAnGE DOWn (dimming)
3 - START LEvEL ChAnGE uP/DOWn (brighten-
ing/dimming) – alternately
3
Parameter size:
1 [byte]
2 - Key Pressed 2 times
4 - Key Pressed 3 times
8 - Key Pressed 4 times
16 - Key Pressed 5 times
32 - Key held Down
64 - Key Released
127 (all)
1 [byte]
Parameter size:

#7: Specifications

Battery type:
ER14250 ½AA 3.6v
Battery life:
est. 2 years (with default settings and
max. 10 pushes per day)
Operating temperature:
0 - 40°C (32 - 104°F)
Eu standards compliance:
RohS 2011/65/Eu
R&TTE 1999/5/EC
Radio protocol:
Z-Wave (500 series chip)
Radio frequency:
868.4 or 869.8 Mhz Eu;
908.4, 908.42 or 916.0 Mhz uS;
921.4 or 919.8 Mhz AnZ;
869.0 Mhz Ru;
Range:
up to 50m (164 ft) outdoors
up to 40m (131 ft) indoors
(Depending on terrain and building
structure)
Dimensions
46 x 34 mm
(diameter x height):
(1.81" x 1.34")
13
!
CAUTION
using batteries other
than specified may
result in explosion.
Dispose of properly,
observing
environ-
mental
protection
rules.
i
NOTE
Radio frequency of
individual
device
must be same as your
Z-Wave
controller.
Check
information
on the box or consult
your dealer if you are
not sure.